<?xml version="1.0"?>
<device eep_size="512" version="01">
<supported_types>
<type priority="2" id="HBW-EBTEST" name="Elektor EBus Test Board">
<parameter const_value="0xE0" size="1" index="0"/>
<parameter const_value="0" size="1" index="1"/>
</type>
</supported_types>
<paramset id="HBW-EBTEST_dev_master" type="MASTER">
<parameter id="LOGGING_TIME">
<logical type="float" unit="s" default="5.0" max="25.5" min="0.1"/>
<physical size="1.0" type="integer" interface="eeprom">
<address index="0x0001"/>
</physical>
<conversion type="float_integer_scale" offset="0.0" factor="10"/>
</parameter>
<parameter id="CENTRAL_ADDRESS" hidden="true">
<logical type="integer"/>
<physical size="4" type="integer" interface="eeprom">
<address index="0x0002"/>
</physical>
</parameter>
<enforce id="CENTRAL_ADDRESS" value="1"/>
</paramset>
<frames>
<frame id="LEVEL_SET" type="#x" channel_field="10" direction="to_device">
<parameter size="1.0" index="11.0" type="integer" param="LEVEL"/>
</frame>
<frame id="LEVEL_GET" type="#S" channel_field="10" direction="to_device"/>
<frame id="INFO_LEVEL" type="#i" channel_field="10" direction="from_device" event="true">
<parameter size="1.0" index="11.0" type="integer" param="LEVEL"/>
</frame>
</frames>
<channels>
<channel index="0" type="MAINTENANCE" count="1" class="maintenance" ui_flags="internal">
</channel>
<channel index="1" type="SWITCH" count="1" physical_index_offset="-1">
<paramset id="hmw_switch_ch_master" type="MASTER" address_step="2" address_start="0x06">
<parameter id="LOGGING">
<logical type="option">
<option id="OFF"/>
<option id="ON" default="true"/>
</logical>
<physical size="0.1" type="integer" interface="eeprom">
<address index="+0"/>
</physical>
</parameter>
</paramset>
<paramset id="hmw_switch_ch_values" type="VALUES">
<parameter id="STATE" operations="read,write,event" control="SWITCH.STATE">
<logical type="boolean" default="false"/>
<physical type="integer" interface="command" value_id="LEVEL">
<set request="LEVEL_SET"/>
<get request="LEVEL_GET" response="INFO_LEVEL"/>
<event frame="INFO_LEVEL"/>
</physical>
<conversion type="boolean_integer" true="200" false="0" threshold="1"/>
</parameter>
</paramset>
</channel>
<channel index="2" type="SENSOR" count="1" physical_index_offset="-1">
<paramset id="hmw_sensor_ch_master" type="MASTER" address_step="2" address_start="0x08">
<parameter id="LOGGING">
<logical type="option">
<option id="OFF"/>
<option id="ON" default="true"/>
</logical>
<physical size="0.1" type="integer" interface="eeprom">
<address index="+0"/>
</physical>
</parameter>
</paramset>
<paramset id="hmw_sensor_ch_values" type="VALUES">
<parameter id="STATE" operations="read,event" control="SWITCH.STATE">
<logical type="boolean" default="false"/>
<physical type="integer" interface="command" value_id="LEVEL">
<get request="LEVEL_GET" response="INFO_LEVEL"/>
<event frame="INFO_LEVEL"/>
</physical>
<conversion type="boolean_integer" true="200" false="0" threshold="1"/>
</parameter>
</paramset>
</channel>
</channels>
</device>